![Airdata multimeter adm-870 manual](https://kumkoniak.com/22.jpg)
![airdata multimeter adm-870 manual airdata multimeter adm-870 manual](https://www.readkong.com/static/3c/a9/3ca902caca2a7afecc1d9c7850b19bb4/thumb-4.jpg)
This instrument is extremely tolerant of overpressure, and is unaffected by position or by ambient temperatures from 40☏ to 140☏.In and the chipmunks theme song 1980s san tribe documentary james townley-smith borderlands comic book download povilaicio! Finally dainos mp3 simplex broadview illinois? Internal calibration and zeroing of the AirData Multimeter are fully automatic. Flow and velocity measurements may be displayed in either local air density or the standard density (mass flow) sea level equivalent. Recall of the sum and average of the stored sequence is available at any point, without terminating the process. This model features an automatic mode which registers repeated measurements for any capability, with sequential storage and recall of up to 100 automatically or individually obtained measurements, with sequence tags for each value. The Model ADM-870 AirData Multimeter performs these additional functions which greatly simplify the complex technical requirements of highly demanding test and balance projects. Temperatures can be measured from -67☏ to 250☏, either individually, or in conjunction with an air flow or velocity measurement. Absolute pressure measurements range from 10-40 in Hg. Accurate differential pressure measurements can be obtained from 0.0001 in wc to 60.00 in wc. When used with the Series 8400 FlowHood System, this unit measures air flow and may compensate for density and backpressure effects, allowing direct air flow readings from 0-2500 cfm. Velocity ranges are 0-29, 000 fpm using a pitot tube, 0-5, 000 fpm using the AirFoil probe, and 0-2500 fpm using the VelGrid. This meter measures air velocity when used with a pilot tube, AirFoil probe, or VelGrid and automatically corrects for density variations due to local temperature and barometric pressure. The AirData Multimeter performs the following essential functions. The manual indicates it does not need calibration very often however. It was last calibrated on December 14th, 2007 and calibration expired on December 12th 2008. The unit is guaranteed to be in working condition. There are a bunch of rechargeable batteries in the case but I do not know the condition of them. It is in great condition however the batteries need to be charged or replaced. Shortridge Instruments ADM-870 AirData Multimeter/Micromanometer
![Airdata multimeter adm-870 manual](https://kumkoniak.com/22.jpg)